Search for:

FX3U-24MR

₹ 6000

1.Power Suppply DC24V

2.8000 steps:2 communication ports:one RS232 (DB9 serial communication port is FX3u

3.Input Point X Component X0-X15, DC24 input, low level effectively.X0-5 high-speed counting input port (default is 12 KHZ).

4.Output Point Y component Y0-Y11 is relay output. Relay output current 5AY0-2 for high-speed output (Max. 26k)

5.Analog Input 6 channels analog input, 12-bit precision, input voltage:0-10V; 0-20mA; Read analog with RD3A command

6.Analog Output 2 channels analog output, 12-bit precision, output voltage:0-10VOutput analog voltage with WR3A command

7.Relay M0-M3071, power-off save range can be set

8.Stepping Point S S0-1023, power-off save range can be set S0-S1023

9.100Ms Timer T0-T199, accumulative power-off save T184-T199

10.10Ms Timer T200-T249, accumulative power-off save T246-T249

11.1Ms Timer T250-T383, T250-255 is accumulated type

12.16-bit Counter C0-C199, power-off save C100-199

13.32-bit Counter C200-C219, power-off save C220-C234

14.32-bit Highspeed Counter C235-255; C235-240 is single-phase counter,.

15.Register D D0-D7999, power-off save range can be set D0-7999

FX3U-24MT

₹ 6000

1.Power Suppply DC24V

2.8000 steps:2 communication ports:one RS232 (DB9 serial communication port is FX3u

3.Input Point X Component X0-X15, DC24 input, low level effectively.X0-5 high-speed counting input port (default is 12 KHZ).

4.Output Point Y component Y0-Y11 is Transister output.

5.Analog Input 6 channels analog input, 12-bit precision, input voltage:0-10V; 0-20mA; Read analog with RD3A command

6.Analog Output 2 channels analog output, 12-bit precision, output voltage:0-10VOutput analog voltage with WR3A command

7.Relay M0-M3071, power-off save range can be set

8.Stepping Point S S0-1023, power-off save range can be set S0-S1023

9.100Ms Timer T0-T199, accumulative power-off save T184-T199

10.10Ms Timer T200-T249, accumulative power-off save T246-T249

11.1Ms Timer T250-T383, T250-255 is accumulated type

12.16-bit Counter C0-C199, power-off save C100-199

13.32-bit Counter C200-C219, power-off save C220-C234

14.32-bit Highspeed Counter C235-255; C235-240 is single-phase counter,.

15.Register D D0-D7999, power-off save range can be set D0-7999

FX3U-14MR

₹ 5000

1.Power Suppply DC24V

2.8000 steps:2 communication ports:one RS232 (DB9 serial communication port is FX3u

3.Input Point X Component X0-X7, DC24 input, low level effectively.X0-5 high-speed counting input port (default is 12 KHZ).

4.Output Point Y component Y0-Y5 is relay output. Relay output current 5AY0-2 for high-speed output (Max. 26k)

5.Analog Input 6 channels analog input, 12-bit precision, input voltage:0-10V; 0-20mA; Read analog with RD3A command

6.Analog Output 2 channels analog output, 12-bit precision, output voltage:0-10VOutput analog voltage with WR3A command

7.Relay M0-M3071, power-off save range can be set

8.Stepping Point S S0-1023, power-off save range can be set S0-S1023

9.100Ms Timer T0-T199, accumulative power-off save T184-T199

10.10Ms Timer T200-T249, accumulative power-off save T246-T249

11.1Ms Timer T250-T383, T250-255 is accumulated type

12.16-bit Counter C0-C199, power-off save C100-199

13.32-bit Counter C200-C219, power-off save C220-C234

14.32-bit Highspeed Counter C235-255; C235-240 is single-phase counter,.

15.Register D D0-D7999, power-off save range can be set D0-7999